1. Device; It can be used in adult, pediatric and neonatal patients
2. The device has 320*240 resolution, 3.5 inch, color LCD TFT screen.
3. Device; It can measure SpO₂ and heart rate.
4. The device; It can measure systolic, diastolic and mean blood pressure.
5. The blood pressure measurement ranges of the device are as follows
In Adult Mode;
Systolic 40-270 mmHg.
Diastolic 10-215 mmHg.
Mean Arterial Pressure 20-235 mmHg .
In Pediatric Mode;
Systolic 40- 200 mmHg.
Diastolic 10-150 mmHg.
Mean Arterial Pressure 20-165 mmHg.
In Neonatal Mode;
Systolic 40-135 mmHg.
Diastolic 10-100 mmHg.< /span>
Average arterial pressure 20-110 mmHg.
6. Pressure unit can be selected as mmHg or KPa.
7. Device SpO₂ measurement range 0- It is 100%. .
11. The device has audible and visual alarms.
12. The device has technical, general and physiological alarms.
13. Alarms should be at different levels as high, medium and low according to their importance. and there are different visual and functional alarms for each level.
14. When multiple alarms are activated at the same time, the device warns for the highest-grade alarm.
15. SpO₂ alarms can be canceled by the user when desired.
16. Systolic, diastolic and mean arterial blood pressures lower and upper alarm values for SpO₂ and pulse alarms It should be adjustable by the user.
17. Audible alarm can be canceled for 2 minutes by pressing a button on the device and activated by pressing the same key again if desired. The device should be able to be switched to silent mode by turning off all sounds such as and key tones by the user, and by pressing the same key, this mode should be exited.
19. The device should be able to display 100 hours of trend data for all parameters, 2 hours of trend graph for SpO₂ and heart rate, and 200 patient records
20. Instant or recorded data can be transferred to PC when requested.
21. Dimensions of the device are 200.8mm.(L)*241mm.(H)*189mm. (D).
24. The cuff hose length of the device is 3m.
25. The total weight of the device including the battery should not exceed 3 kilograms.
26. The device package can be reused for one monitor, adult patient as standard.< /span>
SpO₂ sensor, power cord, manual Supplied with quick reference card, certificate of quality, ingredient list, battery.